n077
Overtorque / LED LCD 0 to 8 0 5.21
Undertorque Setting
Setting Method
Detection (OL3) 0 Disabled ** Detection disabled
1 OT/SpdAgree/Alm Overtorque detect only
(Torq Det at set frequency;
Sel) operation continues
2 OT/RUN/Alm Overtorque detect during
all frequency conditions;
operation continues
3 OT/SpdAgree/Flt Overtorque detect only
at set frequency;
coast to stop
4 OT/RUN/Flt Overtorque detect during
all frequency conditions;
coast to stop
5 UT/SpdAgree/Alm Undertorque detect only
at set frequency;
operation continues
6 UT/RUN/Alm Undertorque detect during
all frequency conditions;
operation continues
7 UT/SpdAgree/Flt Undertorque detect only
at set frequency;
coast to stop
8 UT/RUN/Flt Undertorque detect during
all frequency conditions;
coast to stop
n078
Overtorque / 30 to 200 160 (%) 5.21
Undertorque [100% =
Detection Level drive rated
current ]
(Torq Det
Level)
n079
Overtorque / 0.0 to 10.0 0.1 (Sec) 5.21
Undertorque
Detection Delay
Time
(Torq Det
Time)
n080
On-delay Timer 0.0 to 25.5 0.0 (Sec) 5.19F
(On-Delay
Timer)
n081
Off-delay Timer 0.0 to 25.5 0.0 (Sec) 5.19F
(Off-Delay
Timer)
A1-11
Table A1-1. Drive Parameters (
nXXX
) – Continued
PARAM.
FUNCTION NAME SETTING FACTORY USER PARA.
NO. (ACTUAL DISPLAY)
DESCRIPTION
RANGE SETTING ** SETTING REF.