7
7.12 S: Special Applications
YASKAWA TOEPYAIH6B01A HV600 AC Drive Narrow Bypass Installation & Startup 229
No.
(Hex.)
Name Description
Default
(Range)
S3-06
(321F)
RUN
PI2 Control Proportional
Gain
Sets the proportional gain of the PI2 Control. Set this parameter to 0.00 to disable proportional
control.
1.00
(0.00 - 25.00)
S3-07
(3220)
RUN
PI2 Control Integral Time Sets the integral time for the suction pressure control. Set this parameter to 0.00 to disable the
integrator.
1.0 s
(0.0 - 360.0 s)
S3-08
(3221)
RUN
PI2 Control Integral Max
Limit
Sets the maximum output possible from the integrator. 100.0%
(0.0 - 100.0%)
S3-09
(3222)
RUN
PI2 Control Output Upper
Limit
Sets the maximum output possible from the PI Auxiliary Control function. 100.0%
(0.0 - 100.0%)
S3-10
(3223)
RUN
PI2 Control Output Lower
Limit
Sets the minimum output possible from the PI Auxiliary Control function. 0.0%
(-100.0 - +100.0%)
S3-11
(3224)
PI2 Control Output Level
Sel
Sets the PI2 controller output direction.
0 : Direct Acting (Normal Output)
1 : Inverse Acting (Reverse Output)
0
(0, 1)
S3-12
(3225)
RUN
PI2 Control Disable Mode
Sel
Sets what U5-20 [PI2 Control Output] will output when disabled.
0 : No Output (0%)
1 : Lower Limit (S3-10)
2 : Setpoint
0
(0 - 2)
S3-13
(3226)
RUN
PI2 Control Low Feedback
Lvl
Sets the secondary PI low feedback detection level.
Note:
Parameters S3-04 [PI2 Control Unit Selection], S3-03 [PI2 Control Decimal Place Pos], and S3-
02 [PI2 Control Transducer Scale] set the unit, resolution, and upper limit.
0.00
(0.00 - 600.00)
S3-14
(3227)
RUN
PI2 Control Low Feedback
Time
Sets the secondary PI low feedback detection delay time in seconds. 1.0 s
(0.0 - 25.5 s)
S3-15
(3228)
RUN
PI2 Control High Feedback
Lvl
Sets the secondary PI high feedback detection level.
Note:
Parameters S3-04 [PI2 Control Unit Selection], S3-03 [PI2 Control Decimal Place Pos], and S3-
02 [PI2 Control Transducer Scale] set the unit, resolution, and upper limit.
100.00
(0.00 - 600.00)
S3-16
(3229)
RUN
PI2 Control High Feedback
Time
Sets the secondary PI high feedback detection delay time in seconds. 1.0 s
(0.0 - 25.5 s)
S3-17
(322A)
RUN
PI2 Control Feedback Det
Sel
Sets when the low and high feedback detection multifunction outputs (71h and 72h) for PI2 Control
are active.
0 : While PI2 Control Enabled
1 : Always
Note:
Feedback level detection compares PI2 Control Feedback from analog input H3-xx = 26 [MFAI
Function Selection = PI2 Control Feedback] to these parameters:
• S3-13 [PI2 Control Low Feedback Lvl] for low feedback level detection
• S3-15 [PI2 Control High Feedback Lvl] for high feedback level detection
0
(0, 1)
S3-18
(322B)
RUN
PI2 Control Custom Unit 1 Sets the first character of the PI2 Control custom unit display when S3-04 = 49 [PI2 Control Unit
Selection = Custom(S3-18~20)].
41
(20 - 7A)
S3-19
(322C)
RUN
PI2 Control Custom Unit 2 Sets the second character of the PI2 Control custom unit display when S3-04 = 49 [PI2 Control Unit
Selection = Custom(S3-18~20)].
41
(20 - 7A)
S3-20
(322D)
RUN
PI2 Control Custom Unit 3 Sets the third character of the PI2 Control custom unit display when S3-04 = 49 [PI2 Control Unit
Selection = Custom(S3-18~20)].
41
(20 - 7A)