4.3 Wiring the Power Supply to the SERVOPACK
4.3.5 Wiring Regenerative Resistors
4-24
SERVOPACK Models SGD7S-3R8A, -5R5A, -7R6A, -120A, -180A,
-200A, and -330A
1.
Remove the lead from between the B2 and B3 terminals on the SERVOPACK.
2.
Connect the External Regenerative Resistor between the B1/ and B2 terminals.
3.
Set Pn600 (Regenerative Resistor Capacity) and Pn603 (Regenerative Resistance).
Refer to the following section for details on the settings.
5.18 Setting the Regenerative Resistor Capacity on page 5-54