8.2  Monitoring Methods
8-7
8.2
Monitoring Methods
You can use the data tracing function of the SigmaWin+ or the analog monitor signals of the 
SERVOPACK for monitoring. If you perform custom tuning or manual tuning, always use the 
above functions to monitor the machine operating status and SERVOPACK signal waveform 
while you adjust the servo gains. 
Check the adjustment results with the following response waveforms. 
• Position Control 
• Speed Control 
• Torque Control 
Item 
Unit 
Rotary Servomotor  Linear Servomotor 
Torque reference  %
Feedback speed 
min
-1
mm/s
Position reference speed 
min
-1
mm/s
Position deviation  Reference units 
Item 
Unit 
Rotary Servomotor Linear Servomotor 
Torque reference  %
Feedback speed 
min
-1
mm/s
Reference speed 
min
-1
mm/s
Item 
Unit 
Rotary Servomotor Linear Servomotor 
Torque reference  %
Feedback speed 
min
-1
mm/s