6.10 Software Reset
6.10.3 Operating Procedure
6-49
6.10.3
Operating Procedure
There are the following two methods that you can use to perform a software reset.
Direct connection to the SERVOPACK
Connection through a controller
The procedure for each method is given below.
Direct Connection to the SERVOPACK
1.
Click the Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
2.
Select Software Reset in the Menu Dialog Box.
The Software Reset Dialog Box will be displayed.
3.
Click the Execute Button.
Click the Cancel Button to cancel the software reset. The Main Window will return.
4.
Click the Execute Button.
5.
Click the OK Button to end the software reset operation.
All settings including parameters will have been re-calculated. When you finish this operation, discon-
nect the SigmaWin+ from the SERVOPACK, and then connect it again.
This concludes the procedure to reset the software.