5.1 Manipulating Parameters (Pn)
5.1.4 Write Prohibition Setting for Parameters
5
Basic Functions That Require Setting before Operation
5-9
Restrictions
If you prohibit writing parameter settings, you will no longer be able to execute some functions.
Refer to the following table.
SigmaWin+ Digital Operator
When Writ-
ing Is Pro-
hibited
Reference
Button in
Menu
Dialog Box
SigmaWin+ Function
Name
Fn No. Utility Function Name
Setup
Origin Search
Fn003 Origin Search
Cannot be
executed.
page 7-19
Absolute Encoder Reset Fn008 Reset Absolute Encoder
Cannot be
executed.
page 5-49
Adjusting the Analog Moni-
tor Output
Fn00C
Adjust Analog Monitor Output
Offset
Cannot be
executed.
page 9-8
Fn00D
Adjust Analog Monitor Output
Gain
Cannot be
executed.
page 9-8
Motor Current Detection
Offset Adjustment
Fn00E
Autotune Motor Current
Detection Signal Offset
Cannot be
executed.
page 6-55
Fn00F
Manually Adjust Motor Cur-
rent Detection Signal Offset
Cannot be
executed.
Multiturn Limit Setting
Fn013
Multiturn Limit Setting after
Multiturn Limit Disagreement
Alarm
Cannot be
executed.
page 6-40
Reset Configuration Error
of Option Module
Fn014
Reset Option Module Config-
uration Error
Cannot be
executed.
page 12-46
Vibration Detection Level
Initialization
Fn01B
Initialize Vibration Detection
Level
Cannot be
executed.
page 6-51
Set Origin Fn020
Set Absolute Linear Encoder
Origin
Cannot be
executed.
page 5-51
Software Reset Fn030 Software Reset
Can be
executed.
page 6-48
Polarity Detection Fn080 Polarity Detection
Cannot be
executed.
page 5-27
Tuning-less Level Setting Fn200 Tuning-less Level Setting
Cannot be
executed.
page 8-16
EasyFFT Fn206 Easy FFT
Cannot be
executed.
page 8-98
Parameters Initialize* Fn005 Initialize Parameters
Cannot be
executed.
page 5-10
Tuning
Autotuning without Refer-
ence Input
Fn201
Advanced Autotuning with-
out Reference
Cannot be
executed.
page 8-24
Autotuning with Reference
Input
Fn202
Advanced Autotuning with
Reference
Cannot be
executed.
page 8-35
Custom Tuning Fn203 One-Parameter Tuning
Cannot be
executed.
page 8-42
Anti-Resonance Control
Adjustment
Fn204
Adjust Anti-resonance Con-
trol
Cannot be
executed.
page 8-51
Vibration Suppression Fn205 Vibration Suppression
Cannot be
executed.
page 8-56
Monitor Product Information
Fn011 Display Servomotor Model
Can be
executed.
page 9-2
Fn012 Display Software Version
Can be
executed.
Fn01E
Display SERVOPACK and
Servomotor IDs
Can be
executed.
page 9-2
Fn01F
Display Servomotor ID from
Feedback Option Module
Can be
executed.
Continued on next page.