9.2 Monitoring SERVOPACK Status
9.2.2 Monitoring Status and Operations
9-4
Motion Monitor Window
Operating Procedure
Use the following procedure to display the Motion Monitor and Status Monitor for the SERVO-
PACK.
Select Monitor in the SigmaWin+ Menu Dialog Box.
The Operation Pane and Status Pane will be displayed in the Monitor Window.
Monitor Items
Current Alarm State
Motor Speed
Speed Reference
Internal Torque Reference
Angle of Rotation 1 (number of
encoder pulses from origin within one
encoder rotation)
Angle of Rotation 2 (angle from origin
within one encoder rotation)
Input Reference Pulse Speed
Deviation Counter (Position Deviation)
Cumulative Load
Regenerative Load
Power Consumption
Consumed Power
Cumulative Power Consumption
DB Resistor Consumption Power
Absolute Encoder Multiturn Data
Absolute Encoder Position within One Rota-
tion
Absolute Encoder (Lower)
Absolute Encoder (Upper)
Reference Pulse Counter
Feedback Pulse Counter
Fully Closed Feedback Pulse Counter
Total Operating Time
You can flexibly change the contents that are displayed in the Monitor Window. Refer to the
following manual for details.
Engineering Tool SigmaWin+ Operation Manual (Manual No.: SIET S800001 34)