12.2  Alarm Displays
 12.2.2  Troubleshooting Alarms
12-13
A.042: 
Parameter Com-
bination Error
The speed of program 
jogging went below 
the setting range 
when the electronic 
gear ratio (Pn20E/
Pn210) or the Servo-
motor was changed.
Check to see if the 
detection conditions
*1
 
are satisfied.
Decrease the setting of 
the electronic gear ratio 
(Pn20E/Pn210).
page 5-43
The speed of program 
jogging went below 
the setting range 
when Pn533 or Pn585 
(Program Jogging 
Movement Speed) 
was changed.
Check to see if the 
detection conditions
*1
 
are satisfied.
Increase the setting of 
Pn533 or Pn585.
page 7-14
The movement speed 
of advanced autotun-
ing went below the 
setting range when 
the electronic gear 
ratio (Pn20E/ Pn210) 
or the Servomotor 
was changed.
Check to see if the 
detection conditions
*2
 
are satisfied.
Decrease the setting of 
the electronic gear ratio 
(Pn20E/Pn210).
page 5-43
A.044: 
Semi-Closed/
Fully-Closed 
Loop Control 
Parameter 
Setting Error
The setting of the 
Fully-Closed Module 
does not match the 
setting of Pn002 = 
n.X (External 
Encoder Usage).
Check the setting of 
Pn002 = n.X.
Make sure that the setting 
of the Fully-closed Mod-
ule agrees with the setting 
of Pn002 = n.X.
page 10-6
A.04A: 
Parameter Set-
ting Error 2
For 4-byte parameter 
bank members, there 
are two consecutive 
members with nothing 
registered.
–
Change the number of 
bytes for bank members 
to an appropriate value.
–
The total amount of 
bank data exceeds 64 
(Pn900 × Pn901 > 
64).
–
Reduce the total amount 
of bank data to 64 or less.
–
A.050: 
Combination 
Error 
(The capacities of 
the SERVOPACK 
and Servomotor 
do not match.)
The SERVOPACK and 
Servomotor capaci-
ties do not match 
each other.
Confirm that the follow-
ing condition is met:
1/4 ≤ (Servomotor 
capacity/SERVOPACK 
capacity) ≤ 4
Select a proper combina-
tion of the SERVOPACK 
and Servomotor capaci-
ties.
page 1-9
A failure occurred in 
the encoder.
Replace the encoder 
and check to see if the 
alarm still occurs.
Replace the Servomotor 
or encoder.
–
A failure occurred in 
the SERVOPACK.
–
The SERVOPACK may be 
faulty. Replace the 
SERVOPACK.
–
A.051: 
Unsupported 
Device Alarm
The motor parameter 
file was not written to 
the linear encoder. 
(This applies only 
when not using a 
Serial Converter Unit.)
Check to see if the 
motor parameter file 
was written to the lin-
ear encoder.
Write the motor parame-
ter file to the linear 
encoder.
page 5-18
An unsupported Serial 
Converter Unit or 
encoder (e.g., an 
external encoder) is 
connected to the 
SERVOPACK.
Check the product 
combination specifica-
tions.
Change to a correct com-
bination of models.
–
Continued on next page.
Continued from previous page.
Alarm Number: 
Alarm Name
Possible Cause Confirmation Correction Reference