User Constant Tables
5-17
Dwell Functions: b6
User constants for dwell functions are shown in the following table.
b5-15
PID sleep
function
operation
level
Set the PID sleep function
start level as a frequency.
0.0 to
400.0
0.0 Hz No A A A A A 1B3H
6-108
暂停动作值
b5-16
PID sleep
operation
delay time
Set the delay time until the
PID sleep function starts in
seconds.
0.0 to
25.5
0.0 s No A A A A A 1B4H
6-108
暂停动作延迟
时间
b5-17
Accel/decel
time for PID
reference
Set the accel/decel time for
PID reference in seconds.
0.0 to
25.5
0.0 s No A A A A A 1B5H
6-108
PID 加减速
时间
Con-
stant
Num-
ber
Name
Description
Setting
Range
Fac-
tory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
b6-01
Dwell fre-
quency at
start
The dwell function is used to output
frequency temporarily when driving
a motor with a heavy load.
0.0 to
400.0
0.0 Hz No A A A A A 1B6H
4-21
6-22
起动暂停频
率
b6-02
Dwell time
at start
0.0 to
10.0
0.0 s No A A A A A 1B7H
4-21
6-22
起动暂停时
间
b6-03
Dwell fre-
quency at
stop
0.0 to
400.0
0.0 Hz No A A A A A 1B8H
4-21
6-22
停止暂停频
率
b6-04
Dwell time
at stop
0.0 to
10.0
0.0 s No A A A A A 1B9H
4-21
6-22
停止暂停时
间
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
Run command ON
Output frequency
Timeb6-03
OFF
b6-01
b6-04
b6-02