EasyManua.ls Logo

YASKAWA varispeed G7 CIMR-G7B series

YASKAWA varispeed G7 CIMR-G7B series
495 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Constant Tables
5-83
Fault Trace: U2
User constants for error tracing are shown in the following table.
Con-
stant
Number
Name
Description
Output Signal
Level During
Multi-Function
Analog Output
Min.
Unit
Control Methods
MEMO-
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
U2-01
Current fault
The contents of the current fault.
(Cannot be output.)
-AAAAA80H
当前故障
U2-02
Previous fault The contents of the error that
occurred just prior to the current
fault.
-AAAAA81H
过去故障
U2-03
Reference
frequency at
fault
The reference frequency when
the previous fault occurred.
0.01
Hz
AAAAA82H
预先设定指令
U2-04
Output fre-
quency at
fault
The output frequency when the
previous fault occurred.
0.01
Hz
AAAAA83H
输出频率
U2-05
Output cur-
rent at fault
The output current when the pre-
vious fault occurred.
0.1 A A A A A A 84H
输出电流
U2-06
Motor speed
at fault
The motor speed when the previ-
ous fault occurred.
0.01
Hz
NoAAAA85H
电机速度
U2-07
Output volt-
age reference
at fault
The output reference voltage
when the previous fault occurred.
0.1 V A A A A A 86H
故障输出电压
U2-08
DC bus volt-
age at fault
The main current DC voltage
when the previous fault occurred.
1 V A A A A A 87H
主回路直流电
U2-09
Output power
at fault
The output power when the pre-
vious fault occurred.
0.1
kW
AAAAA88H
输出功率
U2-10
Torque refer-
ence at fault
The reference torque when the
previous fault occurred. The
motor rated torque corresponds
to 100%.
0.1% No No A No A 89H
转矩指令

Table of Contents