SIP & IAX Settings
SIP settings and IAX settings can be foundviaPBX→Advanced Settings.It is wise to
leave the default setting as provided on this page. However, for a few fields, you need
to change them to suit your situation.
SIP Settings
IAX Settings
SIP Settings
1) General Settings
Table 17-1 SIP Settings-General
General Settings
UDP Port
Port used for SIP registrations. The default is 5060.
TCP Port
Port used for SIP registrations. The default is 5060.
TLS Port
Port used for SIP registrations. The default is 5061.
TLS Verify Server
When using MyPBX as a TLS client, whether or not to verify
server’s certificate. It is “No” by default.
TLS Verify Client
When using MyPBX as a TLS server, whether or not to verify
client’s certificate. It is “No” by default.
TLS Ignore
Common Name
Set this parameter as “No”, then common name must be the
same with IP or domain name.
TLS Client Method
When using MyPBX as TLS client, specify the protocol for
outbound TLS connections. You can select it as tlsv1, sslv2 or
sslv3.
RTP Port
Set RTP port range.
DTMF Mode
Set default mode for sending DTMF.Default setting: rfc2833.
Max
Registration/Subsc
ription Time
Maximum duration (in seconds) of a SIP registration. The default
is 3600 seconds.
Min
Registration/Subsc
ription Time
Minimum duration (in seconds) of a SIP registration. The default
is 60 seconds.
Default
Incoming/Outgoing
Registration Time
Default Incoming/Outgoing Registration Time: Default duration
(in seconds) of incoming/outgoing registration.
Register Attempts
The number of SIP REGISTER messages to send to a SIP
Registrar before giving up. Default is 0 (no limit).
Register Timeout
Number of seconds to wait for a response from a SIP Registrar

Table of Contents

Other manuals for Yeastar Technology MyPBX Standard

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yeastar Technology MyPBX Standard and is the answer not in the manual?

Yeastar Technology MyPBX Standard Specifications

General IconGeneral
BrandYeastar Technology
ModelMyPBX Standard
CategoryPBX
LanguageEnglish

Related product manuals