5-49
IM 710105-17E
Commands
5
5.1 List of Commands
Command Function Page
:TRIGger[:ATRigger]:CANFD[:ID]:
IDENtifier:ID:PATTern
Sets or queries the ID condition, which is one of the ID conditions, for CAN
FD bus signal triggering in binary notation.
5-267
:TRIGger[:ATRigger]:CANFD[:ID]:
IDENtifier:MFORmat
Sets or queries the ID frame format (standard or extended), which is one of
the ID conditions, for CAN FD bus signal triggering.
5-268
:TRIGger[:ATRigger]:CANFD[:ID]:
IDENtifier:PFORmat
Sets or queries the ID input format, which is one of the ID conditions, for
CAN FD bus signal triggering.
5-268
:TRIGger[:ATRigger]:CANFD[:ID]:
MSIGnal:MESSage:ITEM
Sets the message item, which is one of the ID conditions, for CAN FD bus
signal triggering.
5-268
:TRIGger[:ATRigger]:CANFD[:ID]:
RTR
Sets or queries the RTR, which is one of the ID conditions, for CAN FD bus
signal triggering.
5-268
:TRIGger[:ATRigger]:CANFD:IDOR?
Queries all IDOR condition settings for CAN FD bus signal triggering. 5-268
:TRIGger[:ATRigger]:CANFD:IDOR:
DATA[:MODE]
Sets or queries the data enable/disable condition, which is one of the IDOR
conditions, for CAN FD bus signal triggering.
5-268
:TRIGger[:ATRigger]:CANFD:IDOR:
IDENtifier?
Queries all identifier settings for the IDOR conditions for CAN FD bus signal
triggering.
5-268
:TRIGger[:ATRigger]:CANFD:IDOR:
IDENtifier:ID<x>?
Queries all ID settings for the IDOR conditions for CAN FD bus signal
triggering.
5-268
:TRIGger[:ATRigger]:CANFD:IDOR:
IDENtifier:ID<x>:HEXa
Sets the ID value, which is one of the IDOR conditions, for CAN FD bus
signal triggering in hexadecimal notation.
5-268
:TRIGger[:ATRigger]:CANFD:IDOR:
IDENtifier:ID<x>:MODE
Sets or queries the ID enable/disable condition, which is one of the IDOR
conditions, for CAN FD bus signal triggering.
5-269
:TRIGger[:ATRigger]:CANFD:IDOR:
IDENtifier:ID<x>:PATTern
Sets or queries the ID condition, which is one of the IDOR conditions, for
CAN FD bus signal triggering in binary notation.
5-269
:TRIGger[:ATRigger]:CANFD:IDOR:
IDENtifier:MODE
Sets or queries the identifier enable/disable condition, which is one of the
IDOR conditions, for CAN FD bus signal triggering.
5-269
:TRIGger[:ATRigger]:CANFD:IDOR:
IDENtifier:MFORmat
Sets or queries the ID frame format (standard or extended), which is one of
the IDOR conditions, for CAN FD bus signal triggering.
5-269
:TRIGger[:ATRigger]:CANFD:IDOR:
IDENtifier:PFORmat
Sets or queries the ID input format, which is one of the IDOR conditions, for
CAN FD bus signal triggering.
5-269
:TRIGger[:ATRigger]:CANFD:IDOR:
MSIGnal<x>:MESSage:ITEM
Sets the message item, which is one of the IDOR conditions, for CAN FD
bus signal triggering.
5-269
:TRIGger[:ATRigger]:CANFD:IDOR:
RTR
Sets or queries the RTR, which is one of the IDOR conditions, for CAN FD
bus signal triggering.
5-269
:TRIGger[:ATRigger]:CANFD:MODE
Sets or queries the CAN FD bus signal trigger mode. 5-270
:TRIGger[:ATRigger]:CANFD:RECes
sive
Sets or queries the CAN FD bus signal trigger recessive level. 5-270
:TRIGger[:ATRigger]:CANFD:SOUR
ce
Sets or queries the CAN FD bus signal trigger signal. 5-270
:TRIGger[:ATRigger]:CANFD:SPOi
nt
Sets or queries the CAN FD bus signal trigger sample point. 5-270
:TRIGger[:ATRigger]:OR?
Queries all edge OR trigger settings. 5-270
:TRIGger[:ATRigger]:OR:CHANnel
<x>
Sets or queries the edge of a channel for edge OR triggering. 5-270
:TRIGger[:ATRigger]:PSI5?
Queries all PSI5 signal trigger settings. 5-270
:TRIGger[:ATRigger]:PSI5:DATA?
Queries all PSI5 signal trigger data settings. 5-270
:TRIGger[:ATRigger]:PSI5:DATA:C
ONDition
Sets or queries the data condition for PSI5 signal triggering. 5-270
:TRIGger[:ATRigger]:PSI5:DATA:D
ECimal
Sets or queries the data for PSI5 signal triggering in decimal notation. 5-270
:TRIGger[:ATRigger]:PSI5:DATA:H
EXa
Sets the data for PSI5 signal triggering in hexadecimal notation. 5-271
:TRIGger[:ATRigger]:PSI5:DATA:P
ATTern
Sets or queries the data for PSI5 signal triggering in binary notation. 5-271
:TRIGger[:ATRigger]:PSI5:DATA:P
FORmat
Sets or queries the data input format for PSI5 signal triggering. 5-271
:TRIGger[:ATRigger]:PSI5:MODE
Sets or queries the PSI5 signal trigger mode. 5-271
:TRIGger[:ATRigger]:PSI5:SETup?
Queries all bus setup settings for PSI5 signal triggering. 5-271
:TRIGger[:ATRigger]:PSI5:SETup:
DATA?
Queries all PSI5 signal trigger data signal settings. 5-271
:TRIGger[:ATRigger]:PSI5:SETup:
DATA:BRATe
Sets or queries the PSI5 signal trigger bit rate (data transfer rate). 5-271
:TRIGger[:ATRigger]:PSI5:SETup:
DATA:DBITs
Sets or queries the data length for PSI5 signal triggering. 5-272