Parameters 275
62.27 MF data 3 value (Follower only) Displays, in integer format, the data received
from the master as word 3.
Parameter 62.03 M/F data 3 selection can be used to select a
target for the received data. This parameter can also be used
as a signal source by other parameters.
0
0…65535 Data received as word 3 in master/follower communication.
62.28 Follower node 2
data 1 value
Displays, in integer format, the data received from the first
follower (ie. follower with node address 2) as word 1.
Parameter 62.04 Follower node 2 data 1 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 1 from follower with node address 2.
62.29 Follower node 2
data 2 value
Displays, in integer format, the data received from the first
follower (ie. follower with node address 2) as word 2.
Parameter 62.05 Follower node 2 data 2 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 2 from follower with node address 2.
62.30 Follower node 2
data 3 value
Displays, in integer format, the data received from the first
follower (ie. follower with node address 2) as word 3.
Parameter 62.06 Follower node 2 data 3 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 3 from follower with node address 2.
62.31 Follower node 3
data 1 value
Displays, in integer format, the data received from the second
follower (ie. follower with node address 3) as word 1.
Parameter 62.07 Follower node 3 data 1 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 1 from follower with node address 3.
62.45 Data set 1 data 1
selection
Parameters 62.4562.50 define a target for the data received
in data sets 1 and 3 from the external controller. These data
sets are used in ModuleBus communication with a “standard
drive” (60.50 DDCS controller drive type = ABB standard
drive).
Parameters 62.9562.100 display the data received from the
external controller in integer format, and can be used as
sources by other parameters.
For example, this parameter selects a target for word 1 of data
set 1. Parameter 62.95 Data set 1 data 1 value displays the
received data in integer format, and can also be used as a
source by other parameters.
None
None None. 0
CW 16bit Control Word (16 bits) 1
Ref1 16bit Reference REF1 (16 bits) 2
Ref2 16bit Reference REF2 (16 bits) 3
Other Source selection (see Terms and abbreviations
on page 92). -
62.46 Data set 1 data 2
selection
Defines a target for the data received as word 2 of data set 1.
See also parameter 62.96 Data set 1 data 2 value.
For the selections, see parameter 62.45 Data set 1 data 1
selection.
None
No. Name/Value Description Def/FbEq16