EasyManua.ls Logo

ABB ACS880-17 - Page 52

ABB ACS880-17
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52 Operation principle and hardware description
L525 FAIO-01 analog I/O extension module
L526 FDIO-01 digital I/O extension module
L536 FPTC-01 thermistor protection module
L537 FPTC-02 ATEX-certified thermistor protection module
Starter for auxiliary motor fan
M600 Trip limit setting range: 1 … 1.6 A
M601 Trip limit setting range: 1.6 … 2.5 A
M602 Trip limit setting range: 2.5 … 4 A
M603 Trip limit setting range: 4 … 6.3 A
M604 Trip limit setting range: 6.3 … 10 A
M605 Trip limit setting range: 10…16 A
Control program
N5000 Winder control program
N5050 Crane control program
N5100 Winch control program
N5200 PCP/ESP control program
N5300 Test bench control program
N5450 Override control program
N7502 Control program for synchronous reluctance motors (SynRM)
N8010 Application programming
Specialties
P902 Customized
P904 Extended warranty
P912 Seaworthy packaging
P913 Special color
P929 Container packaging
Safety functions
Q950 Prevention of unexpected start-up with FSO-xx safety functions module, by activating the Safe
torque off function
Q951 Emergency stop (category 0) with safety relays, by opening the main breaker/contactor
Q952 Emergency stop (category 1) with safety relays, by opening the main breaker/contactor
Q954 Ground fault monitoring for IT (ungrounded networks)
Q957 Prevention of unexpected start-up with safety relays, by activating the Safe torque off function
Q963 Emergency stop (category 0) with safety relays, by activating the Safe torque off function
Q964 Emergency stop (category 1) with safety relays, by activating the Safe torque off function
Q965 Safely limited speed with encoder (+Q972 and +L521 required)
Q971 ATEX-certified safe disconnection function
Q972 FSO-21 safety functions module
Q973 FSO-12 safety functions module
Q978 Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by
opening the main breaker/contactor
Q979 Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by
activating the Safe torque off function
Q982 PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module
Full set of printed manuals in the selected language
Note: The delivery may include manuals in English if the requested language is not available.
CODE DESCRIPTION

Table of Contents

Other manuals for ABB ACS880-17

Related product manuals