EasyManua.ls Logo

ABB FSM4000 - Spare Parts List; Fuses for Transmitter Electronics; Replacing the Fuse

ABB FSM4000
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FSM4000 ELECTROMAGNETIC FLOWMETER | OI/FSM4000-EN REV. E 121
12 Spare parts list
Note
Spare parts can be ordered from ABB Service.
www.abb.com/contacts
Fuses for transmitter electronics
WARNING
Danger due to electric current!
When the housing is open, EMC protection is impaired and
there is no longer any protection against accidental contact.
Power to all connection leads must be switched off.
Replacing the fuse
1. Switch off the power supply. After waiting 40 minutes,
remove the housing cover from the field housing unit.
2. To replace the fuses for shock protection cover
1, loosen
and remove the 3 screws
2.
1
Shock protection cover
2
Fixing screw cover
Figure 66: Removing the shock protection cover
1
Fuse for driver circuit on the backplane
2
Backup fuse for power supply on the backplane
3
Fuses for power supply on the transmitter electronics
Figure 67: Fuses
Item
Designation
Ordering number
1
Driver circuit fuse F103 (0.8 A)
D151F003U18
2
Backup fuse for power supply on backplane (4
A-
T)
D151B003U08
3
Fuse for power supply on the transmitter
electronics
Fuse for 24
V AC/DC (4 A-T)
Fuse for 100 to 230 V AC (1 A-T)
D151B003U08
D151B003U05