20 FSM4000 ELECTROMAGNETIC FLOWMETER | OI/FSM4000-EN REV. E
5 Installation
Installing the sensor
4. Use the appropriate screws for the holes in accordance with
Torque information on page 21.
5. Slightly grease the threaded nuts.
6. Tighten the nuts in a crosswise manner as shown in the
figure. Observe the tightening torques in accordance with
Torque information on page 21!
First tighten the nuts to approx. 50 % of the maximum
torque, then to 80 %, and finally a third time to the maximum
torque. Do not exceed the max. torque.
Figure 22: Tightening sequence for the flange screws