EasyManua.ls Logo

ABB FSO-21 - Page 450

ABB FSO-21
540 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
450 Parameters
200.04 FSO DO status Shows the states of the FSO digital outputs.
200.05 FSO control word 1 Shows the states of the FSO commands.
200.06 FSO control word 2 Shows the states of the FSO commands.
Index Name/Value Description
Bit Name Values
0 Output X113:7 0 = Off, 1 = On
1 Output X113:8 0 = Off, 1 = On
2 Output X113:9 0 = Off, 1 = On
4 Output X114:7 0 = Off, 1 = On
5 Output X114:8 0 = Off, 1 = On
6 Output X114:9 0 = Off, 1 = On
7-15 Reserved
Bit Name Values
0 STO request 0 = Off, 1 = On
1 SSE request 0 = Off, 1 = On
2 SS1 request 0 = Off, 1 = On
3 Reserved
4 SAR0 request 0 = Off, 1 = On
5 SAR1 request 0 = Off, 1 = On
6 Reserved
7 Reserved
8 Reserved
9 Reserved
10 SLS1 request 0 = Off, 1 = On
11 SLS2 request 0 = Off, 1 = On
12 SLS3 request 0 = Off, 1 = On
13 SLS4 request 0 = Off, 1 = On
14 Reserved
15 SDI positive request 0 = Off, 1 = On
Bit Name Values
0 SDI negative request 0 = Off, 1 = On
1 CRC request 0 = Off, 1 = On
2 FSO brake 0 = Off, 1 = On
3 Variable SLS request 0 = Off, 1 = On
4 SS1 modoff allowed 0 = Off, 1 = On
5 SSE modoff allowed 0 = Off, 1 = On
6-15 Reserved