EasyManua.ls Logo

ABB FSO-21 - Page 530

ABB FSO-21
540 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
530 Technical data
Values with the FSE-31 module
1-channel non-
pulsed DI
Logic
STO-output
1-channel non-
pulsed output
Speed estimate
2.6E-08 1.5E-04 2.9E-04 5.8E-04 93.8 0 2 149 83.7 1 c
2-channel
pulsed DI
Logic
STO-output
2-channel
pulsed output
Speed estimate
1.0E-08 1.4E-04 2.8E-04 5.1E-04 98.4 1 3 149 95.9 3 e
2-channel non-
pulsed DI
Logic
STO-output
2-channel non-
pulsed output
Speed estimate
1.1E-08 1.4E-04 2.8E-04 5.3E-04 97.8 1 3 149 94.4 3 e
PROFIsafe
Logic
STO-output
Speed estimate
1.1E-08 1.5E-04 2.9E-04 5.9E-04 99.0 1 3 161 98.6 3 e
3AXD10001287182 C
1) Lowest subsystem SFF
2) Lowest subsystem DC
Subsystems
used in the
safety function
PFH
(1/h)
PFD
avg
PFD
avg
PFD
avg
SFF
1)
HFT SIL MTTF
D
DC
2)
Cat. PL
(T1 = 20 a) (T1 = 2 a) (T1 = 5 a) (T1 = 20 a) (%) (a) (%)
1-channel
pulsed DI
Logic
STO-output
1-channel
pulsed output
Speed
measurement
6.4E-08 9.8E-05 9.9E-04 - 96.8 0 2 1115 96.6 2 d
1-channel non-
pulsed DI
Logic
STO-output
1-channel non-
pulsed output
Speed
measurement
7.9E-08 1.1E-04 1.0E-03 - 93.8 0 2 1114 83.7 1 c
Subsystems
used in the
safety function
PFH
(1/h)
PFD
avg
PFD
avg
PFD
avg
SFF
1)
HFT SIL MTTF
D
DC
2)
Cat. PL
(T1 = 20 a) (T1 = 2 a) (T1 = 5 a) (T1 = 20 a) (%) (a) (%)