Recommended rules for configuration of board positions 1-6:
1. Place the first digital I/O board at board position 1.
2. If it is necessary to reserve digital inputs and outputs for system-I/O and/or panel
I/O, use the last digital I/O board (highest number on the board position).
3. The analog or combined I/O board must be placed at board position 1.
4. Interface board for the Winchester is placed at board position 6.
5. Place the RIO-board to the left of the last board in the rack.
The following rules apply to logical numbering of digital and analog inputs and outputs
as referenced via the programming unit, monitor and program printout:
1. Logical numbering is performed from right to left (board positions 1)
of defined and non-reserved digital inputs and outputs:
1 st digital I/O board counted from right to left in the control cabinet:
' Digital input 1-16 and digital output 1-16.
2 nd digital I/O-board:
' Digital input 17-32 and digital output 17-32.
Etc.
If a digital or combined I/O board is defined as system I/O and/or panel I/O:
- With definition as system I/O or ESAB I/O, digital inputs 9-16 and digital outputs
9-16 on the board in question in the numerical sequence described above are not
included.
- With definition as panel I/O, digital inputs 1-8 and digital outputs 1-8 on the
board in question in numerical sequence are not included.
- The system simply jumps over the reserved physical inputs and outputs on
the board in question with the logical numbering from right to left in such a
way that the logical numbering has a consecutive number sequence 1,2, 3 etc.
2. Logical numbering on the defined analog I/O board:
Physical outputs 1-4 on the board are numbered logically as analog output
ports 21-24.
Physical inputs 1-4 on the board are numbered logically as analog input
ports 31-34.
3. Logical numbering on the defined combined I/O board:
Physical outputs 1-2 on the board are numbered logically as analog output ports 21-22.
4. RIO-board DSQC 239 is placed physically in a position one number higher then defined
due to same double size of the board.
Description
The parameter boards I/O 1 to I/O 6 are used to define which are installed at
board positions. ,_
Sub-menu
I/O TYPE
Guide text
1/01 = Board position I/O 1
1/0 6 = Board position I/O 6
etc.
Def. range
0 = No board at the board position in question.
8 = Digital input/output board DSQC 223
Equipped with maximum 6 boards.
12 = Analog input/output board DSQC 209.
Equipped with maximum 1 board.
20 = Winchester interface board DSQC 227
Equipped with maximum 1 board
40 = Combined input/putput board DSQC 224.
INSTALLATION S3