Note! The guide texts are showing up only if the link is undefined. To change an
already defined link, all linked I/O:s must be cleared and then defined again.
5.2.4.8
PRINTER
Description
Menu selection for defining that a printer is connected to the system. The printer can
be used for program and error code printouts. In arc welding systems, the printer can
also be used for welding data printout.
Menu
IN/OUT + PRINTER
Information text
PRESENT VALUE = NOT DEFINED
= No printer connected
PRESENT VALUE = DEFINED
= Printer connected
Default value
No printer connected
Menu selection
DEFINE = printer connected
UNDEF = no printer connected
BREAK = no change required
Parameter
If a printer is connected to the control system, the parameter BAUD RATE is used
to determine the data transmission speed for printer printout.
Guide text
BAUD RATE = Def.range
300 = Transmission speed 300 Baud (bit/second).
1200 = Transmission speed 1200 Baud.
Default value
300 = Transmission speed 300 Baud.
5.2.4.9
MONITOR (display screen)
Description
The parameter MONITOR BOARD is used to define the function readout on the
monitor display screen of program and error code buffer. The control system must
be equipped with a monitor (option) before activation of this parameter.
Menu
IN/OUT + MONITOR
Def. range
0 = No readout on monitor display screen.
1 = if LCD-screen is used.
2 = if CRT-screen is used.
Default value
0 = No readout on monitor display screen.
INSTALLATION S3
5:21