5.2.4.19A
EM-STOP (Emergency stop)
Description
The parameter DIG.OUTPUT RESET states if the general digital outputs should
be set to zero at emergency stop. The outputs are restored to its former condition
when the emergency stop is reset and the system is taken in operation mode
again or if the stand by button is pressed.
Menu
SAFETY + EM-STOP
Info text
PRESENT VALUE = 0
= Parameter is passive
Guide text
DIG. OUTPUT RESET=
Def.range
0 = Emergency stop have no influence on the outputs
1 = Outputs will be reset at emergency stop.
Default value
0
Warning!
If the parameter DIG.OUTPUT RESET is set to 1:
It is very important that the peripheral equipment is adapted to that all outputs
are reset at emergency stop and automatically restored to its former condition
when the emergency stop is reset.
5.2.4.19B
AUTOK (AUTO control)
Under this menufunctions in AUTO mode can be blocked. When a function is
choosen to be not permitted and a corresponding key is pressed, the following
fault statement is shown on the display "14 AUTO MODE/LOCKED
COMMAND". The functions are available as sub-menus to menu AUTOK and are
the following:
INSTALLATION
5:42