Note
Port 24 can be defined but the system then issues +/- 20 mA instead of +/-10 V.
Control of wire speed reference
Parameter I
The parameter PARAM MIN (M/MIN) defines the minimum wire speed.
Menu
WIRE SP +VALUE
Guide text
PARAM MIN (M/MIN)
Def. range
0.0 - 50.0 m/min (o -1968 inch/min)
Default value
0 m/min
Parameter II
The parameter PARAM MAX (M/MIN) defines the maximum wire speed.
Menu
Resulting question
Guide text
PARAM MAX (M/MIN)
Def. range
0.0 - 50.0 m/min (0 -1968 inch/min)
Default value
50.0 m/min
Parameter III
The parameter REF MIN (V) defines the minimum wire speed reference.
Menu
Resulting question.
Guide text
REFMIN(V)=
Def. range
-10.0-+10.0 V
Default value
0V
Parameter IV
The parameter REF MAX (V) defines the maximum wire speed reference.
Menu
Resulting question.
Guide text
REFMAX(V)=
Def. range
-10.0
-
+10.0 V
INSTALLATION ~~~~ S3
5:54