Default value
10.0 V
Note
If it is not possible to scale a permissible conversion curve with the parameter
values, this sequence can not be concluded, and the system will request parameter
I again. This can happen if the values entered lies outside the permitted values or
if the minimum value entered is higher than the maximum value. The sequence
can always be concluded by entering the default values.
5.2.4.25
RESEQ
Parameter controlled renumbering
Description
The renumbering function parameter (RESEQ) is associated with an editing
instruction with the same name. The function parameter is initially set to the
value 1 which means that renumbering during editing is permitted. Renumbering
is not permitted when the parameter is set to the value 0. If an attempt is then
made to use the function, the following error message is presented: "NOT
ALLOWED COMMAND".
Menu
OPTION + RESEQ
Info text
PRESENT VALUE =1
Guide text
RESEQUENCE ALLOWED =
Def.range
0 = Renumbering during editing not allowed
1 = Renumbering during editing allowed
Default value
1
5.2.4.26
SWELD (Spot Weld)
Description
The function parameter SWELD must be activated to get the weld function under
the P-button. The parameters SWELD and GLUE can not be activated at the
same time, because both uses the P-button. MH/ASM can be activated together
with SWELD or GLUE. See Programming Manual S3 (3HAB 0002-2),
chapter 12, for more detailed information.
Menu
OPTION + SCAN + SWELD
Info text
PRESENT VALUE = 0
Guide text
SWELD =
INSTALLATION S3
5:55