Def.range
0 = The weld instruction can not be programmed. Execution of earlier
programmed instructions are however permitted.
1 = The weld instruction can be programmed with the P-button on the prog. unit.
Default value
0
5.2.4.27
SWL, (Spot Weld Interface)
Description
The parameter SWELD must be activated to get the SWI- function.
Menu
OPTION + SCAN + SWELD=1 + SWI
Info text
PRESENT VALUE = 0
Guide text
SWI =
Def.range
0 = The SWI instruction cannot be programmed or executed.
1 = Communication between robot and weld controller is performed via a
standard I/O, DSQC 223.
Default value
0
Menu
Resulting question after SWI=1.
Guide text
Board position=
Def. range
The I/O-board can be placed in a optional position and receives I/O-number in the ^
ordinary way. The standard function with sub-programs for control of the welding
controller can be used even when the parameter SWI is activated.
5.2.4.28
RADR (rack address) (RIO board DSQC 239, see also chapter 5.2.4.7.2)
Description
The rack-address in question is set in decimals.
Menu
RADR
Guidetext
RACK-ADDRESS =
Def.range
0-63
Note! Please note that addressing is different from ABB decimal to Alen-Bradley octal.
Some PLC:s first address is equal to ABB address 0.
INSTALLATION S3
5:56