Loading...
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working area.
2
Article number is specified in Re-
quired tools and equipment on
page 119.
If the lamp is not lit, trace the fault by:
inspecting whether the signal lamp is broken.
If so, replace it.
inspecting cable connections.
measuring the voltage in the connectors of
motor axis 6 (=24V).
inspecting the cabling. Replace the cabling if
a fault is detected.
3
120 Product manual - IRB 460
3HAC039842-001 Revision: P
© Copyright 2012-2018 ABB. All rights reserved.
3 Maintenance
3.3.9 Inspecting the signal lamp (option)
Continued