NoteAction
xx1800000158
Fit the fan unit sheets around the motor and fasten
them to each other by tightening the six screws.
5
xx1800000160
Lift the box so that it does not rest directly on the
robot and secure the box against the motor with
the two tightening screws.
Tighten them properly so that the box is firmly
attached to the motor.
6
Connecting the fan cabling
NoteAction
xx1800000161
Remove the rear cover plate.1
xx1800000162
Fit the customer connection plate.2
Continues on next page
Product manual - IRB 6700 105
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
2 Installation and commissioning
2.7.2 Installing the motor cooling fan (option)
Continued