NoteAction
Required oil level: 0 - 10 mm below the oil
plug hole.
Remove the oil dispenser and refit the
protective cap to the nipple.
7
Tightening torque: 24 NmRefit the vent hole plug.8
Note
After all repair and maintenance work in-
volving oil, always wipe the robot clean
from all surplus oil. The robot color can
otherwise be discolored.
9
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section First test
run may cause injury or damage on
page 26.
10