NoteAction
Tightening torque: 10 Nm.
xx1300000772
Refit the wrist cover. In order not to dam-
age the cable harness when the wrist cover
is refitted, use this method:
1 Hold the cover slightly tilted below
the wrist.
2 Put the cable harness inside the
cover.
3 Lift the cover, still tilted.
4 Move the upper part of the cover into
position.
5 Secure the cover with its attachment
screws.
3
See figure above!Foundry Plus:4
Refit protection plugs.
If used, refit the DressPack cable package
on the wrist.
5
Pendulum Calibration is described in Oper-
ating manual - Calibration Pendulum, en-
closed with the calibration tools.
Re-calibrate the robot.6
Axis Calibration is described in Calibrating
with Axis Calibration method on page 798.
General calibration information is included
in section Calibration on page 787.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further described in First test run may
cause injury or damage on page 26.
7
284 Product manual - IRB 6700
3HAC044266-001 Revision: N