NoteAction
WARNING
Before continuing any service work, follow the safety
procedure in section The brake release buttons may
be jammed after service work on page 205!
7
xx1300000743
Refit the push button guard to the SMB cover.8
Press the push buttons 1 to 6, one at a time, to make
sure that the buttons are moving freely and do not
stay in any locked position.
9
Reconnect the battery, if it has been disconnected.10
See Updating revolution counters
on page 794.
Update the revolution counters if the battery has been
disconnected.
11
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further de-
scribed in First test run may cause injury or damage
on page 26.
12
Product manual - IRB 6700 295
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the brake release unit