NoteAction
Person 1, working at the side hole:
xx1300000745
Use caution and push the cable harness
into the wrist.
Tip
This step is best performed by two persons
working together:
• Person 1: Put one hand inside the
side cover hole and take a hold of
the cable harness.
• Person 2: Take a hold of the cable
harness from inside the wrist.
• Together: Move the cable harness
past the axis-5 motor and into the
wrist.
7
Person 2, working at the wrist:
xx1300000746
xx1700000340
Refit the metal clamp axis-4 inside the arm
tube.
Note
The screws are reached from outside the
upper arm!
8
xx1700000339
Continues on next page
422 Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.5.5 Replacing the lower arm
Continued