3 Maintenance
3.3.6. Inspection, oil level gearbox axis 6
3HAC022033-001 Revision: K166
© Copyright 2004-2011 ABB. All rights reserved.
Analysis of water content in oil, gearbox axis 6 (Foundry Prime)
When changing oil, check for water content in oil.
6. Add oil if required. Art. no. is specified in Required
equipment on page 164.
Detailed in section Oil change,
gearbox axis 6 on page 215.
7. Refit the oil plug, filling. Tightening torque: 24 Nm.
8.
WARNING!
Do not mix oil types! If wrong oil is refilled, the gearbox
must be rinsed as detailed in section Type of oil on
page 192.
Action Note
If: Then....
1. More than 2% water in oil:
With more than 2% water content
there is a risk for corrosion in the
gearbox and reduced viscosity in
the oil.
Replacement of gearbox axis 6 is required
every two years
xx0600003155
A: Water content in oil from gearbox
axis 6
B: Months or hours in operation
C: Replacement of gearbox axis 6
Continued
Continues on next page