Abbott FreeStyle Precision Pro User Manual

Abbott FreeStyle Precision Pro
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operators Manual
for Healthcare Professionals

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Abbott FreeStyle Precision Pro and is the answer not in the manual?

Abbott FreeStyle Precision Pro Specifications

General IconGeneral
Measurement MethodElectrochemical
Sample TypeCapillary Whole Blood
Test Time5 seconds
Operating Temperature Range10°C to 40°C (50°F to 104°F)
Operating Humidity Range10% to 90% RH (non-condensing)
Device TypeBlood Glucose Monitoring System
Power Source2 x AAA batteries
Measuring RangeGlucose: 20 to 500 mg/dL
Sample Size0.6 μL
Measurement RangeGlucose: 20 to 500 mg/dL, Ketones: 0.0 to 8.0 mmol/L
Sample Volume0.6 μL
Battery LifeApproximately 1000 tests

Summary

1. Overview

Important Safety Instructions

Provides critical safety warnings and precautions for using the meter, including dangers of misuse and supervision.

2. Using the Meter

3. Patient Test

Operating Guidelines for All Samples

Provides essential guidelines for accurate patient test results, including handling and strip usage.

Patient Test Procedure - FreeStyle Precision Pro Glucose

Step-by-step procedure for performing a glucose test using the FreeStyle Precision Pro meter.

Patient Test Procedure - Precision Xceed Pro Glucose

Step-by-step procedure for performing a glucose test using the Precision Xceed Pro meter.

Patient Test Procedure - Ketone

Step-by-step procedure for performing a ketone test using the appropriate test strips.

4. Control Test

Operating Guidelines for Control Solution Testing

Essential guidelines for obtaining optimal quality control results using the FreeStyle Precision Pro system.

Control Test Procedure - Glucose

Procedure for performing glucose control tests to verify meter and strip performance.

Control Test Procedure - Ketone

Procedure for performing ketone control tests, applicable when ketone testing is enabled.

8. Review Setup

Meter Configuration

Details configuration settings for the meter, managed via the data management system.

10. Data Upload

Docking Station Upload

Procedure for uploading data from the meter to the data management system using the docking station.

Wireless Transfer (if enabled)

Explains automatic data upload via wireless network once the meter is properly configured.

11. Troubleshooting

Troubleshooting Patient Test Results

Describes conditions causing erroneous patient test results and their possible reasons.

Troubleshooting Out-of-Range Control Test Results

Provides a checklist to resolve out-of-range control test results.

Troubleshooting Out-of-Range Linearity Test Results

Offers steps to troubleshoot linearity test results that fall outside the expected range.

Troubleshooting Wireless (if enabled)

Addresses issues related to wireless connectivity, signal strength, and data upload problems.

Troubleshooting Barcode Scanning

Provides solutions for problems encountered during barcode scanning, including isolation bag use.

Error Messages

Lists error messages, their explanations, and recommended actions to resolve meter issues.

Technical Support Instructions

Steps to prepare for contacting Abbott technical support, including collecting test results.

12. Maintenance

Replacing the Strip Port Module

Step-by-step guide for removing and replacing the meter's strip port module.

Replacing the Batteries

Procedure for installing new AA batteries into the meter, ensuring correct polarity.