105 Appendix A: Glossary
fabian Therapy evolution | SW V5.1.x
Ref: 121003.EN / Date: 26Jan2021
Appendix A: Glossary
Term
Definition
Apnea
Temporary inability to breath.
Atelectasis
The collapse or closure of a lung resulting in reduced or absent gas
exchange.
Audible
Able to be heard.
Bias Flow
The continuous flow of gas responsible for replenishing oxygen and
removing carbon dioxide (CO
2
) from the patient circuit.
DUOPAP
Time triggered, time cycled pressure SIPPVs at two separate pressure
levels.
Bpm
Breaths-per-minute (applies to each spontaneous, triggered and
mandatory).
Checksum
A digit representing the sum of the correct digits in a piece of stored or
transmitted digital data, against which later comparisons can be made
to detect errors in the data.
COM
Communication interface with system.
Corticosteroid
Any of a group of steroid hormones produced in the adrenal cortex or
made synthetically. There are two kinds: glucocorticoids and
mineralocorticoids. They have various metabolic functions, and some
are used to treat inflammation.
CSV
Comma Separated Values.
Derecruitment
Can occur due to the following respiratory episodes:
Low tidal volume (TV) ventilation
Inadequate positive end-expiratory pressure (PEEP)
Use of high FiO
2
(absorption atelectasis)
DIO
Digital Input / Output interface. Relay digital signals from sensors,
transducers, and mechanical equipment to other electrical circuits and
devices.
FiO
2
Fraction of Inspired Oxygen. A fraction of oxygen in the volume being
measured.
FRAM
Ferroelectric Random-Access Memory.
Generator
Patient attachment for delivering CPAP, used with nasal prongs and
mask.
IP
Ingress Protection rating.
IR
Infrared radiation [
wavelength about 700 nanometres
(nm)].
Leaks
Leakage from patient or system tubings connections.
LED
Light Emitting Diode.
LNCS
Low Noise Cable Sensors.
MRI
Magnetic Resonance Imaging.
MRT
Magnetic Resonance Therapy.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ACUTRONIC fabian and is the answer not in the manual?

ACUTRONIC fabian Specifications

General IconGeneral
TypeNeonatal and Pediatric Ventilator
ManufacturerACUTRONIC Medical Systems AG
Modelfabian
Respiratory Rate1 - 150 bpm
FiO2 Range21 - 100%
HFOV Frequency5 - 20 Hz
Power Supply100-240 V AC, 50/60 Hz
Modes of VentilationSIMV, CPAP, HFOV
Tidal Volume Range2 to 300 ml
PEEP/CPAP0-20 cmH2O
Inspiratory Time0.1 to 3 seconds
Flow Rate2 - 30 L/min
Flow SensorIntegrated
Pressure Limit10-80 cmH2O