ACUTRONIC fabian Specifications

General IconGeneral
TypeNeonatal and Pediatric Ventilator
ManufacturerACUTRONIC Medical Systems AG
Modelfabian
Respiratory Rate1 - 150 bpm
FiO2 Range21 - 100%
HFOV Frequency5 - 20 Hz
Power Supply100-240 V AC, 50/60 Hz
Modes of VentilationSIMV, CPAP, HFOV
Tidal Volume Range2 to 300 ml
PEEP/CPAP0-20 cmH2O
Inspiratory Time0.1 to 3 seconds
Flow Rate2 - 30 L/min
Flow SensorIntegrated
Pressure Limit10-80 cmH2O

Summary

Warnings, Cautions, and Notices

Always Observe (fabian)

Presents critical safety warnings and precautions for proper ventilator use.

System Overview

Contraindications

Specifies conditions where the ventilator should not be used.

System Functions and Displays

Control Panel Options

Describes the key elements and buttons of the device's control panel.

Ventilation Menu

Details navigation and operation within the ventilation settings menu.

System Operation

Preparing for Operation

Steps to prepare the device before starting operation, including connections.

System Start-up

Procedure for powering on the ventilator and initial self-tests.

System Shutdown

Instructions for safely powering off the ventilator.

Emergency Shutdown

Procedure for immediate shutdown in emergency situations.

Device Checks

Outlines essential pre-use checks and calibration steps for the ventilator.

Configurations Menu

Calibration

Guides through calibration procedures for sensors and device functions.

Ventilation Parameter Settings

Covers adjusting parameters like O2 Flush, leak compensation, and units.

Alarms

Alarm Limits Menu

Allows manual or automatic adjustment of alarm limits and volume.

Alarm Causes and Solutions

Lists common alarms, their causes, and recommended solutions.

Power Management

Battery Operation

Information on battery life, charging, and monitoring.

Ventilation Modes and Parameters

Ventilation Parameters

Explains various ventilation parameters like CPAP, PEEP, and I-time.

Maintenance and Service

Setting Ranges and Parameters

Technical Specifications

Essential Performance

Defines critical performance functions and compliance standards.

Electromagnetic Compatibility Statement