User Manual MIC 900 / MIC 1100 / MIC 3000
Aggregate modules, unlike aggregate buttons, can be programmed permanently and saved.
Also see „
Editing program steps“, item 4.3.1, page 22
The current status of the aggregates are shown under „Aggregate and relay display“, item
2.6.3, page 17
2.6.2 Process display
In the process display all the steps and the corresponding processes are
shown. The currently selected or currently running step is highlighted in
blue. This shows you clearly which processes have already run and
which are still to come.
2.6.3 Aggregate and relay display
All the aggregates which have been configured for the current process, together with their operating
status, are shown In this list
0 – Aggregate off
1 – Aggregate on
2.6.4 Messages (system status messages)
All digital inputs which have been configured as messages in a
process or program and their operating status are shown here.
0 – Contact open
1 – Contact closed
Messages are for information only and are not sent to
the recording program „VisuNet“.
Aggregate which have been