User Manual MIC 900 / MIC 1100 / MIC 3000
33
Issue 17.08.2021_00
Please note
Every 60 seconds the Fc value is calculated from the actual core temperature and added up.
Since temperatures below 55 degrees lead to an Fc value of zero, the adding up only starts
from this temperature threshold.
Example for FC value 70:
( )
=
10
70
1070
CaturecoretemperT
FC
Example for FC value 121:
( )
=
10
1.121
10121
CaturecoretemperT
FC
6.2 Transient changes to the nominal values
In operating mode the nominal values can be transiently changed. This means the new nominal
values are only valid for the current step and are not saved.
Press the relevant nominal value box and use the numerical pad that will appear to enter the new
value. Confirm with „Enter“.
Please note
If a PIN entry is requested, the Administrators (from V00.07) function, item 8.7, page 42 has
been enabled. This means that changes can only be made by specific operators.
6.3 Batch number during operation
When the installation is in operation you can check on the batch number or change it. Press on the
„Program“ box at the top on the left on the standby page.
The batch description will be shown in the „Program namebox. If you want to change the description,
press this box. A keypad in the pre-set system language will appear and you can now rename the
batch. Confirm with Enter“.
Press the Program“ box again and the batch number will be hidden and the program name will
appear instead.
Please note
If a PIN entry is requested the Administrators (from V00.07) function, item 8.7, page 42 has
been enabled. This means that changes can only be made by specific operators.