6.4 Switching into the next step or previous step
Switching into the next or previous step works exactly the same as described in item Selecting a
step“, item 2.3, page .
Please note
If a PIN entry is requested the Administrators (from V00.07) function, item 8.7, page 42 has
been enabled. This means that changes can only be made by specific operators.
6.5 Pausing a program
With the „Hold“ button in the lower task bar you can pause a program which is in operation.
Push the button „Hold “:
the description of control button 4 will change from „Holdto „Start“
„Hold“ and „Stop“ buttons will be flashing
on the info bar the message „Program manually paused“ will be shown
all relays are de-energised
the operating time will be paused
Push the „Start“ button:
the buttons stop flashing
The relays are re-energised
Operating time continues to run
Please note
If a PIN entry is requested the Administrators (from V00.07) function, item 8.7, page 42 has
been enabled. This means that changes can only be made by specific operators.
6.6 Single step control
As soon as a program step has finished the controller will automatically switch into the next step. If the
nominal value Single step has been enabled in a process (it has been configured by the service
technician) you can decide in programming mode what you want to happen at the end of the program
step:
"Step = Stop" function: the controller switches into pause mode and the message Hold: single
step control will appear on the status bar, the "Start" and „Stop“ button are flashing.
If you want the current process to continue, raise the nominal value that led to the termination of
the process. Confirm with the „Start“ button.
- If you want the program to continue with the next process, either switch into the next process
manually or change the nominal value „Process“ to Go“. Then confirm with the Start“ button
- If you want to terminate the program, press the „Stop“ button.
"Step = Go" function: Controller will automatically switch into the next step.
6.7 Alarm signal
If an alarm incident has occurred, for example through digital inputs, limit value alarms or sensor
failure, the „Step box will be flashing with the word „Alarm“. On the info bar you can see the alarm
and the cause (e.g. chamber sensor break). Press the „Step box to acknowledge the alarm and to
stop the horn. The message will remain on the info bar.