1 Introduction
1.1 Overview
Processors MIC 900, MIC 1100 and MIC 3000,
with user-friendly touch panel, 7“ TFT display with resistive touch technology, several interfaces and a
housing of standard industrial quality, are designed for use in universal cooking and smoking
chambers as well as climatic smoke and maturing chambers.
In its standard version the controller is equipped with
4 Pt100 temperature inputs and
2 inputs which can be converted to Pt100 and current 4-20mA / voltage 0-10V or thermocouples
(compliant with DIN EN 60584).
The following interfaces allow communication: LAN/Ethernet and USB Serial Port.
In order to adapt the controller for specific purposes each control loop can be used as a 2-point
controller, XP controller or with PID behaviour.
MIC 900:
The standard version has 16 relay outputs
(12 normally open contacts and 4 changeover contacts).
MIC 1100:
In its standard version the controller is equipped with 18 relay outputs
(14 normally open contacts and 4 changeover contacts).
MIC 3000:
The standard version has 24 relay outputs
(16 normally open contacts and 8 changeover contacts).