6TANTP507-1E
TOTAL ACCESS
3000/3010
NTP-507
Page 3 of 6
Total Access
®
3000/3010 System Manual
© 2002, ADTRAN, Inc.
19. From the Inband Interface Menu, write down the settings for the following
parameters:
1.) IP Address
2.) Subnet Mask
3.) Gateway
20. Once all the above information has been written down, press <Esc> twice to return
to the Provisioning Menu.
21. From the Provisioning Menu, select option 4, SNMP, and press <Enter>.
22. From the SNMP Menu, write down the settings for the following parameters:
1.) Read Community
2.) Write Community
3.) Trap Host 0 IP Address
4.) Trap Host 1 IP Address
5.) Trap Host 2 IP Address
6.) Trap Host 3 IP Address
7.) Trap Host Method
23. Once all the above information has been written down, press <Esc> once to return
to the Provisioning Menu.
24. From the General Menu, select option 5, TL1, and press <Enter>.
25. From the TL1 Menu, write down the settings for the following parameters:
1.) Shelf Number
2.) Target ID (TID)
26. Once all the above information has been written down, press <Esc> three times to
return to the Main Menu.
1.1.3 Materials Required
Total Access 3000/3010 System Controller Unit (SCU).
1.2 Unpack and Inspect the Replacement SCU
CAUTION
Electronic modules can be damaged by static electrical discharge. Before
handling modules, wear an anti-static discharge wrist strap to prevent damage
to electronic components. Place modules in anti-static packing material when
transporting or storing. When working on modules, always place them on an
approved anti-static mat that is electrically grounded.