TOTAL ACCESS 3000/3010
DLP-710
Page 2 of 4
© 2002, ADTRAN, Inc.
Perform Steps Below in the Order Listed
1.2 Detailed Level Procedure 710
NOTE
Each three-pin alarm header is wired the same way for the specified alarm.
1. Determine whether the external alarm reporting device uses a normally open or
normally closed circuit for alarm relay.
2. Using standard telco cross connect wire, determine and cut the length required to
reach from the alarm headers to the alarm-reporting device.
3. Using wire strippers, strip 1 inch to 2 inches from both ends of the wire.
4. Using a wire-wrap gun, wire wrap one strand to the center pin (common) from the
Total Access alarm relay header, and the other strand to either the “NO” (normally
open) or “NC” (normally closed) pin on the relay header. See Figure 1.
5. Connect, using wire wrap or lugs, as appropriate, the two wires to the appropriate
terminals on the external alarm relay device being used.
1.3 Followup Procedures
Once this procedure is complete, return to the procedure which called out this DLP and
continue with the tasks indicated there.