6TANTP514-1E
TOTAL ACCESS
3000/3010
NTP-514
Page 6 of 12
© 2002, ADTRAN, Inc.
Total Access
®
3000/3010 System Manual
Perform Steps Below in the Order Listed
2.) Push the ejector tab up and closed against the HTU-C faceplate.
2. Provision the HTU-C
If Module Auto-Provisioning is enabled on the SCU, and if the new cards are of
the same type as the former, the provisioning of the former access cards of the
two Total Access 3000 slots will be written to the new access cards upon
installation. If this is an initial installation, the units will require provisioning to
appropriately configure them out of the factory default states.
1.) Logon to Total Access system (see DLP-716, located in the System
Manual, for detailed logon procedure).
2). Check to ensure the HTU-C line cards are correctly provisioned
according to circuit parameters. Under the Provisioning menu, set
numbered option, Network Source, to Auto MUX. This option causes
the HTU-C to look to the ON-LINE MUX for its data in the event of a
protection switch between the MUX modules.
3.) Ensure the provisioning of both the MAIN and AUX HTU-Cs is
identical, except for the following options:
a.) Provision the MAIN unit to OOS-M mode.
b.) Provision the AUX unit to the OOS-U mode.
4.) Enable protection switching:
a.) Access the MAIN Menu of the HTU-C in the odd-
numbered (MAIN) slot.
b.) Select Option 7, Protection Configuration.
c.) Select Option 1, Protection Mode.
d.) To enable protection switching, select Option 1, Enable.
NOTE
Unless the AUX circuit is in the OOS-U mode, the operator will not be able
to change the Protection mode of the MAIN HTU-C.