Page 6 of 10
© 2003, ADTRAN, Inc.
Perform Steps Below in the Order Listed
Rate (BER) on the line.
1. INHIBIT – Inhibits APS operation.
2. ALLOW – Allows APS operation.
Select the desired option by typing the corresponding number and press <Enter>.
3. From the Protection Configuration Menu select option 4, BER Line Threshold, and
press <Enter>.
This option sets the BER threshold which, when exceeded, will trigger an APS
switch.
1. > 1x10
-9
2. > 1x10
-8
3. > 1x10
-7
4. > 1x10
-6
5. > 1x10
-5
6. > 1x10
-4
7. > 1x10
-3
Select the desired option by typing the corresponding number and press <Enter>.
4. From the Protection Configuration Menu select option 1, APS Lockout Status, and
press <Enter>.
This option will INHIBIT or ALLOW the Working module to perform an APS
switch to the Offline module when it is the Online (transmitting to the network)
module.
1. INHIBIT
2. ALLOW
Select the desired option by typing the corresponding number and press <Enter>.
5. Return to the Primary MUX Main Menu by pressing <Esc>and proceed to the next
section.