EasyManua.ls Logo

ADTRAN Total Access 3000 - Page 397

ADTRAN Total Access 3000
511 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Total Access
®
3000/3010 System Manual
© 2003, ADTRAN, Inc.
6TADLP741-1E
TOTAL ACCESS 3000/3010
DLP-741
Page 5 of 8
Perform Steps Below in the Order Listed
3. As an example, from the Daily Threshold Menu select option 1, Code
Violation…….S, and press <Enter>.
1. Set Alarm Threshold 125
2. Set Alarm Enable Off
Set the Alarm Threshold by selecting option 1, Set Alarm Threshold, and inputting the
desired threshold. Finally, enable the alarm by selecting option 2, Set Alarm Enable,
and setting to On. This will cause that alarm to be issued if the set threshold value is
exceeded.
4. Return to the Performance Monitoring Menu by pressing <Esc>.
5. From the Performance Monitoring Menu select option 6, STS1 Far-End Daily
Thresholds, and press <Enter>.
1. Code Violation L
2. Errored Second L
3. Severely Errored Second L
4. Unavailable Second L
5. Code Violation P
6. Errored Second P
7. Sev Errored Second P
8. Unavailable Second P
6. For an example, from the Far-End Daily Threshold Menu select option 2, Errored
Second……L, and press <Enter>.
1. Set Alarm Threshold 100
2. Set Alarm Enable Off
Set the Alarm Threshold by selecting option 1, Set Alarm Threshold, and inputting the
desired threshold. Finally, enable the alarm by selecting option 2, Set Alarm Enable,
and setting to On. This will cause that alarm to be issued if the set threshold value is
exceeded.

Table of Contents