Technical data
Advantech-DLoG DLT-V83 Series Manual V1.31 Page 137 of 178
14.4. Environmental conditions
14.4.1. DLT-V83 without integrated UPS
Operating temperature -30 to +50 °C
In accordance with EN 60068-2-1/2
Storage temperature -30 to +65 °C; specification according to EN 60068-2-1/2
Relative humidity 10% to 90% at 40 °C relative humidity, noncondensing;
specification according to EN 60068-2-3
Mechanical vibration
and shock resistance
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
14.4.2. DLT-V83 with integrated UPS (optional)
Operating temperature -10 to +50 °C
Charging temperature 0 to +45 °C (internal device temperature)
Storage temperature -20 to +60 °C; specification according to EN 60068-2-1/2
Relative humidity 10% to 90% at 40 °C relative humidity, noncondensing;
specification according to EN 60068-2-3
Mechanical vibration
and shock resistance
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
For details, see section 10.2 Integrated UPS (optional).