Essential safety instructions
Advantech-DLoG DLT-V83 Series Manual V1.31 Page 15 of 178
2.3.3. Risks during installation/commissioning
Before connecting and disconnecting the cable cover with lithium-ion batteries, the
DLT-V83 must be currentless.
Before connecting and disconnecting the cable cover: Disconnect the main power
cable from the power supply.
2.3.4. Risks during handling/running operation
Disconnecting the DLT-V83 with integrated UPS from the electric power source
Because of the lithium-ion batteries, the integrated UPS may still carry current
even if the DLT-V83 itself is switched off.
Reason: If the the DLT-V83 has been configured to also start without <Power>
button and ignition in the "DLoG Config" program, this setting will need to be
changed first.
Otherwise, the DLT-V83 will restart after a short pause as long as there is
available battery capacity.
Shut down the DLT-V83 via the operating system function
Disconnect from the power source.
Open the cable cover.
Unplug the UPS battery.
Vehicle EMERGENCY-OFF switch does not switch off the DLT-V83 with
integrated UPS
If a DLT-V83 with integrated UPS is installed in a vehicle, the EMERGENCY-
OFF switch of the vehicle has no effect on the DLT-V83.
This also effects the peripherals supplied by the device.
2.3.5. No repair/replacement of the lithium-ion batteries
If the lithium-ion batteries are faulty, the entire cable cover, including the
integrated batteries, must be replaced.