Reasonably foreseeable misuse
Page 156 of 178 DLT-V83 Series Manual V1.31 Advantech-DLoG
16. Reasonably foreseeable misuse
16.1. General
Observe the permissible environmental conditions
Observe correct voltage ranges.
16.2. Mobile application on vehicles
Ensure that supply lines are fused correctly.
Read the labeling on the cable and connect the power supply cable with the correct
polarity.
Cut the power supply cable as short as possible. This avoids tangled cables and
improves the quality of the power supply.
Observe the vehicle manufacturer’s instructions for connecting additional loads, for
instance, in conjunction with an emergency shut-off switch.
Be sure that the connection of the line is as directly as possible to the battery and
not to power supply lines with a great deal of interference (e.g. the engine power
supply) or otherwise affected by consumers.
Connect the power supply cable to a suitable place. Ensure that the connecting
cable has an adequate cross section and ampacity at the connection point.
16.3. Stationary use with AC power supply unit
Please observe that the switch of the Advantech-DLoG power supply cable must be
set to On in order to be able to start the DLT-V83.