Chapter 9 287
BERT
Using the External Frame Trigger Function with the EDGE Format
8. Press Configure Triggers > Ext Frame Trigger Delay.
9. Change the delay value by rotating the knob slowly to find the range of delay values that display a
Ready status.
NOTE Although the delay value can be entered in 0.25 units, the actual uplink burst position can
be changed in 1.0 symbol units.
10. If the PDCH is synchronized by a delay value within a ±3 symbol range, choose the center value to set as
the frame trigger delay.