Settings and Adjustments
Configuring the device on a PC
4
How to configure Monitor
Configure this if "Monitor" is set in “Function (→page 211)”.
How to configure Network Camera Monitor
Configure this if "Network Camera Monitor" is set in “Function (→page 211)”.
How to configure Option Relay Control
Configure this if "Option Relay Control" is set in “Function (→page 211)”.
Entry Description Settings Default values
Station Number Configure the station to monitor (station
number). This cannot be configured for
IX-MV7-*, IX-MV, IXW-MA, or a VoIP
Phone.
3-32 digits -
Entry Description Settings Default values
Network Camera Configure the monitoring network
camera.
Select from the registered
network cameras.
-
Note
• When controlling relay output for multiple stations, processing may take some time and control may be delayed.
Entry Description Settings Default values
Station List Configure a station to control relay
output.
This cannot be configured for IX-MV, IX-
DA(-*), or IX-BA. Multiple (unlimited)
stations can be configured.
Check "Enable" for the station for
which to perform contact output
(multiple selections allowed).
-
Output Time Configure the output time for relay
output, for the station to control.
• 0 (Momentary): Pressing the
Speed Dial button will cause
relay output to continue.
Pressing the Speed Dial button
again stops relay output.
• 200 - 2000 [msec]: Select this
when configuring a value from
200 to 2000 msec (by 200
msec). Enter the time in
"Output Time [msec / sec]
*1
."
• 3 - 600 [sec]: Select this when
configuring a value from 3 to
600 sec (by 1 sec). Enter the
time in "Output Time [msec /
sec]
*1
."
0 (Momentary)
TLS Configure whether to enable encryption
for optional relay communication. If this
is set to "Enable," also configure "Option
Relay Control Key."
• Enable
• Disable
Disable
Option Relay Control Key Configure the encryption key for optional
relay communication when "TLS" is set
to "Enable." Relay output can be
controlled if this matches the "Option
Relay Control Authentication Key" of the
station to perform relay output.
1 - 20 digits -