In the CLI
To use the CLI to configure radio resource management information elements in the RRM IEprofile, access the
CLI in config mode and issue the following command:
(host) (config)#wlan rrm-ie-profile <profile>
Configuring Beacon Report Requests
The beacon report requests are sent only to 802.11k-compliant clients that advertise Beacon Report Capability
in their RRM Enabled Capabilities IE. The beacon request frames are sent every 60 seconds.
The content of the report requests can be defined in the Beacon Report Request profile using the WebUI or
CLI.
In the WebUI
To select the information to be sent in beacon report requests using the WebUI:
1. Navigate to Configuration>Advanced Services>All Profile Management.
2. Expand the Wireless LAN menu and select Beacon Report Request.
3. Select the Beacon Report Request profile you want to configure.
4. Define the settings described in the table below, then click Apply Changes to save your settings.
Parameter Description
Interface This field is used to specify the Radio interface for transmitting the Beacon Report Request
frame. It can have a value of either 0 or 1. The default value is 1.
Regulatory Class This option is used to specify the Regulatory Class field in the Beacon Report Request frame. It
can be set to one of the following: -
n 1 (for 5 GHz band)
n 12 (for 2.4 GHz band)
Channel This option is used to set the Channel field in the Beacon Report Request frame. The Channel
value can be set to one of the following: - the channel of the AP (when Measurement Mode is
set to either 'Passive' or 'Active-All channels') - 0 (when Measurement Mode is set to 'Beacon
Table') - 255 (when Measurement Mode is set to 'Active-Channel Report')
Randomization
Interval
This value is used to set the Randomization Interval field in the Beacon Report Request frame.
The Randomization Interval is used to specify the desired maximum random delay in the
measurement start time. It is expressed in units of TUs (Time Units). A Randomization Interval
of 0 in a measurement request indicates that no random delay is to be used. This field can be
given a value in the range (0, 65535). The default value is 0.
Measurement
Duration
This value is used to set the Measurement Duration field in the Beacon Report Request frame.
The Measurement Duration is set to the duration of the requested measurement. It is
expressed in units of TUs. This field can be given a value in the range (0, 65535). The default
value is 0.
Table 100: Beacon Report Request Settings
AOS-W 6.5.3.x | User Guide Virtual APs | 425