In the CLI
To activate a specific regulatory file loaded on the switch, use the following command:
ap regulatory activate <filename>
To return to the factory default regulatory-cert, use the following command:
ap regulatory reset
In a master-local-standby deployment, the file syncing profile can be enabled to ensure that the regulatory-cert
that is stored on the master is shared with its subordinate switches. File syncing is enabled by default, with a
default sync time of 30 minutes. The sync time can be set between 30 to 180 minutes, To configure the file
syncing profile, use the following commands
(host) (config) #file syncing profile
(host) (File syncing profile) #file-syncing-enable
(host) (File syncing profile) #sync-time 30
Related Show Commands
To view the version of Regulatory Cert currently active on all switches, execute the following command:
(host)#show switches regulatory
To view the file synching profile settings, execute the following command:
(host)#show file syncing profile